Platinum Solution 6 G./Liter
€35.70*
Available, delivery time: 1-2 days
Product information "Platinum Solution 6 G./Liter"
Platinum Electrolyte with 6 Gramm Platinum per Liter!
Platinum Bath - Platinizing with Betzmann Electroplating
Platinum is characterized by high abrasion resistance and gives a noble gray surface.
Alternative: White palladium
The platinum bath from Betzmann Galvanik deposits corrosion-resistant, very bright and shiny platinum layers up to a thickness of 0.5 - 1.0 µm.
It is suitable for both decorative and technical applications and is very well suited for pin, bath and pad electroplating!..
Operating data:
Platinum content: 6.0 g/L
pH-value: <1
Density: 1.08 g/ml, increasing
Working conditions:
Voltage: from 3 volts
Bath temperature: 30 - 40 °C
Exposure time: 2 - 4 min.
Anode material: platinized titanium
Anode/cathode surface: 1 : 1
Fabric movement: required
Recommended speed: 2 - 8 cm/sec.
Deposition rate: approx. 11 mg/Amin; approx. 0.5-1.5 A/dm2
Bath movement: recommended
Precipitation data:
Hardness: 500 HV
Layer thickness: max. 1.0 µm
Fineness: 99,9%
Delivery form: Ready to use 6 g/L Platinium
Features | Applications |
High concentration of platinum – 6 grams per litre |
Suitable for brush plating both decorative and functional items such as jewellery and electrical connectors |
Operating Conditions and Deposit Data
Voltage Range | 3.0 – 5.0 volts |
Temperature | 20 – 25 °C (25 °C preferred) |
Platinum concentration | 6 g/l |
Electrode | Platinum - Carbon |
Platinum content in plate | Above 99.9% |
Plating Rate at (3.5 volts, Platinum electrode) | Approx. 0.25 micron per minute (spot) – see notes) |
Hardness | 405 Hv |
Density of deposit | 21.4 g/cm3 |
Electrical resistivity of deposit | 9.8 micro ohms/cm |
Stress | Not determined |
Special storage requirements | None |
Shelf life | Over 2 years |
Health and Safety classification | Irritant |
Special considerations | None |
Transport (UN number) | 2796 |
Notes:
- We strongly advise against the use of stainless steel anodes for most of our plating processes.
- Higer voltages give greater plating rates, however more gas is liberated and a mist mask is recommended.
- Plating rates are calculated over a sample area which is permanently covered by swab.
- Will plate directly onto freshly prepared nickel or stainless steel.
Hazard statements
H314 Causes severe skin burns and eye damage.
Precautionary statements
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P302 IN CASE OF CONTACT WITH SKIN:
P352 Wash with plenty of water.
P332 If skin irritation occurs:
P313 Get medical advice/attention.
P362 Take off contaminated clothing.