Skip to main content Skip to search Skip to main navigation

Flat Anode - Aluminum Anode 100x50x2 mm

Product information "Flat Anode - Aluminum Anode 100x50x2 mm"

Flat anode - aluminum anode for bath electroplating - for brighter chrome plating.

Our new type of aluminum electrode deposits the chromium III brighter during plating and prevents the yellow tint that usually occurs with nickel electrodes.

 

Dimensions: 100 x 50 x 2 mm 

 

   

 

 

Similar Items

Anode sleeve fuzzy
Anode pad / tampon / anode sleeve / fuzzy sleeve / replacement fabric pad puffy from Betzmann Galvanik.    This puffy fabric pad / anode sleeve or also called tampon is absolutely recommended for all plating processes. Optimally suitable for all coatings and electrolytes.  The coating of larger areas is also quite fast with this pad.   The insertion hole is larger than the electrode and therefore it happens that the moist  anode pad slips off. Therefore, fix the pad on the electrode with a small rubber band.    

€2.38*
Chromplating - Chrome solution
Chrome electrolyte - chrome plating with Betzmann Galvanik   Chrome plating by yourself with high-quality chrome electrolyte from Betzmann Galvanik  A layer of chromium protects a wide variety of components from oxidation and corrosion. In addition, the workpiece is given a visually appealing appearance. Our electrolyte is based on chrome(III). While chromium(VI) was originally used in the industrial process, chromium(III) electrolytes are increasingly being used because they have a significantly lower impact on man and nature. This electrolyte contains all our know-how - we were able to make it significantly brighter and more efficient. Current densities up to 20A/dm² can be achieved. Usually chrome is deposited in the layer system copper - nickel - chrome. The intermediate layer of nickel provides additional protection against corrosion, as chrome layers show microcracks. T   Of course, the chrome electrolyte is suitable for all processes such as bath electroplating and pen plating (or pad plating). When chromium plating, always wear the necessary protective equipment such as safety goggles, gloves and protective clothing and only work in a well-ventilated room.   Parameters (these may vary, please test): Bath electroplating: 1.5-6V (approx. 3V recommended at 10cm distance) pin plating: 3-7V (approx. 4-5V recommended) Current density: 4-24A/dm² (up to 50A/dm² with bath movement) Working temperature 20-50°C (25°C recommended) deposition rate: 0.06µm/min at 10A/dm²   The most important advantages at a glance:  is equally suitable for bath electroplating and pen plating / pad plating high adhesive strength and abrasion resistance high hardness up to 1200 HV extremely large current density range appealing optics Color of the chrome layer is very similar to the result of hexavalent chrome baths heating of the electrolyte is not necessary (temperature range 15-50°C, preferably 15-30°C) high reflection and beautiful gloss higher permissible metal impurities than with other processes, thus easier to use    To achieve a perfect result with the chrome electrolyte, the appropriate anodes are required for the galvanic process used. Anodes made of aluminum, platinized titanium, platinum or iridium are recommended. For pen plating, graphite, nickel or stainless steel anodes can be used if necessary. With nickel or stainless steel anodes, however, it is important to ensure that the pad is washed out well in between so that the metal contamination that arises does not contaminate the electrolyte and the chromium layer.   Aluminium anodes have proven to be particularly advantageous, they are particularly cost-effective and the electrolyte retains its excellent color. If you do not have any, we recommend that you order them directly from us.   Identification of the mixture: Chrome Electrolyte (contains chromium hydroxide sulfate, boric acid, ammonium chloride, ammonium formate) Signal word: Caution H-phrases: H317: May cause an allergic skin reaction. P phrases: P261: Avoid inhalation of aerosol. P280: Wear protective gloves / eye protection. P302 + P352: IF ON SKIN: Wash with plenty of water. P333 + P313: If skin irritation or rash occurs: Get medical advice/attention. P101: If medical advice is needed, have container or label at hand. P102: Keep out of the reach of children.             

Content: 0.1 Liter (€116.60* / 1 Liter)

From €11.66*
Anoden Stoffpad dick Mehrlagig
Anodenstoffpad  - Anodenhüllen dick mehrlagig - Ersatzhüllen für die Tampon Galvanik von Betzmann Real Gold   Dieser dicke Pads besteht aus mehreren zusammen genähten Lagen Stoff und eignet sich hervorragend für die Beschichtung größerer Flächen, aber auch für Teile mit Gittern wie z.B. einKühlergrill  usw. Am unteren Ende befinden sich 2 Einschublöcher für den Anodenstab. Falls dieser sich oben schon durch den Stoff gearbeitet hat, kann man den Pad durch Einstecken in das andereEinschubloch weiterhin benutzen. Bitte vor Anwendung den Pad gründlich durchnässen, sonst leitet er nicht.     Cotton Sleeve Big: This durable cotton anode Sleeves are custom designed to reach into tight recessed areas. Easy on, easy off, no rubber bands.     

€2.50*
Nickel Electrode 6mm
Features "Nickel Electrode 6 mm from Betzmann Galvanik unalloyed rod anode made of pure nickel Ø 6 mm x 100 mm longer lengths on request as sacrificial anode for nickel plating by means of pin / tampon electroplating, reduced nickel electrolyte consumption, nickel layers are mainly used as diffusion barrier for gold plating of copper or as intermediate layer for tin plating Material sample with defined purity grade Ni 99.6 for comparative investigation of material properties Standard electrode for experiments in electrochemistry (electroplating, electrolysis, ion migration, determination of electrochemical potentials, conductivity titration, conductometric titration etc.) Material: nickel Degree of purity: 99.6 Diameter: 6 mm Length: 100 mm      

€13.70*