Galvanic Cleaner Electrocleaner – Metal Cleaning Before Electroplating
€5.90
Available, delivery time: 1-2 days
Product information "Galvanic Cleaner Electrocleaner – Metal Cleaning Before Electroplating"
Galvanic Cleaner Electrocleaner – Professional Metal Cleaning Before Electroplating
Perfect Surface Preparation for Strong Adhesion and High-Quality Electroplated Coatings
The Galvanic Cleaner Electrocleaner from Betzmann Galvanik is a powerful professional degreasing solution for cleaning and preparing metal surfaces before electroplating.
Thorough degreasing is one of the most important steps in electroplating technology. Even the smallest residues such as oils, grease, polishing compounds, waxes, silicones, fingerprints or other organic contaminants can negatively affect the adhesion and quality of electroplated coatings.
The Electrocleaner reliably removes interfering contaminants and creates a clean, activated and optimally wettable metal surface. This provides the ideal foundation for uniform, strongly adherent and high-quality electroplated coatings.
Suitable for numerous electroplating processes such as:
Gold plating
Silver plating
Nickel plating
Copper plating
Zinc plating
Chrome plating
Rhodium plating
Other electroplating applications
A professional coating always starts with perfect surface preparation.
Your Advantages at a Glance
Professional galvanic degreaser for metal surfaces
Removes oil, grease, polishing residues and organic contaminants
Ideal preparation before electroplating processes
Improves adhesion of subsequent metal coatings
Suitable for both non-electrolytic and electrolytic cleaning
Suitable for tank plating, pen plating and tampon plating
Supports bright and uniform coating results
Easy application
Suitable for hobby users, workshops and professional applications
Why Degreasing Before Electroplating Is Essential
The quality of every electroplated coating depends greatly on proper surface preparation.
Even very small amounts of contamination can cause problems such as:
Poor coating adhesion
Peeling or flaking of the deposit
Spotting and stains
Uneven coating surfaces
Poor wetting during electroplating
The Galvanic Cleaner Electrocleaner ensures an optimally prepared metal surface and improves the reliability and quality of the following plating process.
Suitable Materials
The Electrocleaner is suitable for many conductive metals and metal alloys, including:
Steel
Stainless steel
Copper
Brass
Bronze
Nickel
Silver
Other electroplatable metals
For sensitive materials, we recommend testing on an inconspicuous area before use.
Application Methods
1. Non-Electrolytic Cleaning
The cleaner can be used without electrical assistance.
Application:
Immerse the workpiece in the Electrocleaner.
Allow it to work for several minutes depending on the contamination level.
Move the workpiece slightly if required.
Rinse thoroughly with water.
Continue directly with the next electroplating preparation step or coating process.
2. Electrolytic Cleaning with Stainless Steel Electrode
For particularly thorough cleaning results, the Electrocleaner can also be used electrolytically.
This method effectively removes stubborn organic residues such as oil, grease and polishing compounds.
Recommended application:
Electrode: Stainless steel electrode
Voltage: approx. 4 volts
Process: Electrolytic degreasing
Cleaning time: Depending on contamination and workpiece size
The stainless steel electrode offers excellent durability and long service life and is ideally suited as a counter electrode for electrolytic cleaning.
After cleaning:
Rinse the workpiece thoroughly
Do not touch the cleaned surface with bare hands
Continue immediately with the next electroplating step
Use in Electroplating Processes
Recommended process sequence:
Cleaning → Rinsing → Activation → Electroplating
A clean and grease-free surface is essential for:
Excellent adhesion
Uniform layer formation
Brilliant surfaces
Reproducible results
The Electrocleaner is therefore an important part of every professional electroplating setup.
Typical Applications
Ideal for:
Jewellery electroplating
Gold plating
Silver plating
Repair plating
Electronics
Printed circuit boards
Precision engineering
Metal finishing
Restoration work
Workshops
Industrial coating applications
Practical Tips for Best Results
✔ Remove heavy contamination before cleaning
✔ Use clean tools and containers
✔ Do not touch cleaned surfaces with bare hands
✔ Rinse thoroughly after degreasing
✔ Continue with the next plating step immediately to prevent renewed contamination
Avoid Common Problems
Poor coating adhesion:
→ Surface was not sufficiently cleaned or degreased.
Spots or uneven coatings:
→ Oil, grease or polishing residues remain on the surface.
Coating peeling after plating:
→ Surface preparation was insufficient.
Technical Information
Product:
Galvanic Cleaner / Electrocleaner
Application:
Metal cleaning before electroplating
Processes:
Non-electrolytic cleaning
Electrolytic cleaning
Recommended counter electrode for electrolytic cleaning:
Stainless steel electrode
Recommended voltage:
Approx. 4 volts
Suitable for:
Tank plating
Pen plating
Tampon plating
Safety Information
Wear safety glasses and suitable protective gloves.
Avoid contact with skin and eyes.
Use only in well-ventilated areas.
Observe the safety data sheet.
Do not release into the environment.
Quality from Betzmann Galvanik
The Galvanic Cleaner Electrocleaner is a professional surface preparation product for users who require reliable and high-quality electroplating results.
A perfect coating always begins with a perfectly cleaned surface. With the Electrocleaner, you create the ideal foundation for bright, uniform and permanently adherent metal coatings.
Signal word Danger
Hazard statements for physical hazards
H290 May be corrosive to metals.
Hazard statements for health hazards
H314 Causes severe skin burns and eye damage.
P264 Wash hands thoroughly after handling
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303+P361+P353 IF ON SKIN (or hair): Immediately remove all contaminated clothing. Rinse skin with water/shower.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P363 Wash contaminated clothing before reuse.
Other hazards
Results of PBT and vPvB assessment The mixture is not considered to be persistent, bioaccumulative, or toxic (PBT) or very persistent or very bioaccumulative (vPvB).