Skip to main content Skip to search Skip to main navigation

PET Bottle 50ml

Product information "PET Bottle 50ml"

 

PET laboratory bottles are suitable for food! After damage to the hygienic packaging no exchange or return!

 

Properties PET laboratory bottle: Properties screw cap:

Nominal volume: 50 ml Originality: Yes

Rim full volume: 70 ml Height: 20.3 mm

Diameter: 38 mm Thread: 28 ROPP

Height: 88 mm Color: White

Inner diameter opening: 21,9 mm Sealing insert: EPE Sealing insert

Thread: 28 ROPP Material: PE-HD

Color: Brown Surface: corrugated, matt

Material: PET

Maximum label height: 38 mm

Detail description Laboratory bottle:

 

50 ml PET syrup bottle brown, translucent with glossy surface.

Thread 28 ROPP - suitable for caps with tamper evidence.

PET slant shoulder or syrup bottles are mainly used for pharmaceutical products and in the cosmetic field.

PET bottles can be used for a wide range of filling products, this plastic bottle is also approved for food and is therefore food safe.

This PET container is very good residue emptying.

Detail description 28 mm screw cap:

 

Screw cap 28 ROPP with tamper evidence.

An EPE plastic sealing insert in the cap ensures perfect sealing.

 

 

Similar Items

Anode sleeve fuzzy
Anode pad / tampon / anode sleeve / fuzzy sleeve / replacement fabric pad puffy from Betzmann Galvanik.    This puffy fabric pad / anode sleeve or also called tampon is absolutely recommended for all plating processes. Optimally suitable for all coatings and electrolytes.  The coating of larger areas is also quite fast with this pad.   The insertion hole is larger than the electrode and therefore it happens that the moist  anode pad slips off. Therefore, fix the pad on the electrode with a small rubber band.    

€2.38*
Stainless Steel Electrode 6mm
Stainless Steel Electrode 6mm:   This electrode is ideal for chrome stripping and electro-cleaning. To swap over to a stainless steel electrode, simply loosen the existing electrode and fit in the new one.  Stainless steel electrodes should not be used for any other processes such as the metal can cause contamination  of the plating solution resulting in considerable wastage of gold metal.    Selecting the best electrode for the job is very important.  

€5.90*
Silver Electrode
Pure silver electrode for silver plating from Betzmann Galvanik   Product Features "Silver Electrode 6 mm unalloyed rod anode made of pure silver, produced by electrolytic refining dimensions: Ø 6 mm x 100 mm material sample with defined purity Ag 99,99 / Ag 4N Pad Electroplating: as anode for electroplated silver plating, as electroplated coating silver is widely used to reduce the contact resistance and to improve the solderability of contact parts electrode in electrolysis, element collections, investigation of material properties as silver ionization electrodes for hygienic operation of a humidifier by active disinfection of the water Fine silver 999.9/000 has the highest electrical and thermal conductivity of all metals and is also used in research, electrical engineering, medicine, for the production of colloidal silver, for silver pen drawing and occasionally for jewelry making. Material: Silver Purity: 99,99 (4N) Diameter: 6 mm Length: 100 mm     Features Benefits Made from pure silver, it dissolves in the plating solution The silver in the anode replaces the silver from the plating solution, so you can save between 40% and 50% on the cost of solution. It can also save you time as once you’ve dipped your swab in the plating solution, you don’t have to keep dipping it back – the silver from the anode gets plated instead. If you intend to rely on this, we recommend you mix our Thickener with the Silver Plating Solution to make sure the swab doesn’t dry out and electrical contact is maintained.  

€53.60*
Kupfer Elektrode 6mm
Kupferstabanode - Kupfer Elektrode 6mm zum selber verkupfern von Betzmann Galvanik Diese Elektrode wurde entwickelt, um bei der Beschichtung mit unseren Kupferlösungen verwendet zuwerden. Die Kupferionen tauschen sich so schneller aus und Sie erzielen ein schnelles und besseresErgebnis in der Beschichtung. Reines Kupfer 99,9 %      Copper Electrode: To plate copper alkali or acid please use this copper electrode.   Features Benefits Made from pure copper, it dissolves in the plating solution The copper in the electrode replaces the copper from the plating solution, so you can save between 40% and 50% on the cost of solution. It can also save you time as once you’ve dipped your swab in the plating solution, you don’t have to keep dipping it back – the copper from the electrode gets plated instead. If you intend to rely on this, we recommend you mix our Thickener with the Copper Plating Solution to make sure the swab doesn’t dry out and electrical contact is maintained.      

€6.80*
Edelstahl Elektrode dünn 4mm
  Edelstahlelektrode 4mm - dünn, passend in unseren Handgriff:   Diese Elektrode ist in der Vielzahl von Fällen für alle Arbeitsschritte optimal geeignet.  Für die Benutzung der kleinen Pads und/oder Beschichtung kleiner Flächen wird i.d.R. der dünneAnodenstab  verwendet.   Edelstahl-Elektroden können bei anderen Beschichtungsprozessen eine Kontamination derBeschichtungslösung verursachen. Hier empfiehlt sich dann eine andere Art von Anodenstäben zubenutzen, z.B. die Graphitelektrode oder Platinelektrode.   Edelstahlelektrode: Länge ca. 9,5 cm, Durchmesser 4mm     Stainless Steel Electrode: This electrode is ideal for chrome stripping and electro-cleaning. To swap over to a stainless steel electrode, simply loosen the existing electrode using the allen key which comes free with the wand, and fit in the new one. Stainless steel electrodes should not be used for any other processes such as the metal can cause contamination of the plating solution resulting in considerable wastage of gold metal.  Selecting the best electrode for the job is very important.      

€7.00*
Platinum Electrode
Platinum electrode from Betzmann-Galvanik:   We know that when plating with gold or silver, you want to achieve only the best results and this is achieved by using our platinum electrode (platinized titanium). This will more than meet your requirements. It hardly wears out and leaves no black spots or stains when plating. For top quality gold plating, we recommend the use of this electrode.   Care should be taken to clean the electrode carefully after each use!     Properties "Platinum Electrode 6 mm Platinum electrode (platinized titanium with a platinum layer of 2.5 µm platinum) Ø 6 mm x 100 mm Standard electrode for experiments in electrochemistry (electroplating, electrolysis, ion migration, determination of electrochemical potentials, etc.) Spare platinum electrode for Hofmann decomposition apparatus, electrolyzer Platinum-coated titanium anodes are among the classic anode materials for electroplating because they combine the excellent electrochemical properties of platinum with the good corrosion properties of titanium. They are characterized by a long service life at high current density and are versatile in use. They are equally suitable for platinum and ruthenium baths, for hard chrome plating, as bright rhodium baths and for cathodic corrosion protection. The standard platinum layer thickness is 2.5 μm.   In order to achieve the best results when plating with gold (adhesive gold bath, bright gold plating bath) or silver, they are indispensable.   This platinum electrode will more than meet your requirements, it hardly wears out and leaves no black spots or stains when plating. For top quality gold plating, I recommend using this electrode.   Other possible applications: Water electrolysis/separation of hydrogen and oxygen, water disinfection, production of chlorates (chlorate synthesis) and perchlorates.   Recommended operating data:   Operating voltage from 3 volts distance anode/workpiece surface 5 cm anodic current intensity (specific current density) max. 75 A/dm² (7.5 mA/mm² = 750 mA/cm²), i.e. a multiple of the values typical in electroplating (0.5 ... 5 A/dm²) pH value: 0 - 11 Bath temperature max. 60 °C    

€49.00*
Carbon Electrode 6mm
Graphite round rod - Graphite rod anode - Graphite electrode for gold plating.  Graphite electrodes are ultimate for all coatings. The advantage is that in some coatings with stainless steel electrodes, the dislodged metal parts disturb the coating. This does not happen with graphite electrodes, because graphite also filters out contaminated liquids. With bath electroplating, they also need to be replaced occasionally as they slowly dissolve during the plating process.   With pad electroplating, simply loosen the screw on the handle and replace with a new one.   Diameter 6 mm, length approx. 9 cm    Features Used for Doesn’t contaminate Cleaner Activating and electro-cleaning  Its resistive properties help to heat the solution you’re plating with Chromium plating, which needs to be plated at 25 degrees celsius; its natural heating action helps to maintain the solution’s optimal temperature Low cost Can be used for all plating processes but carbon electrodes deteriorate over a period of time and discolour swabs (discolouration does not affect the plating quality)    

€5.90*
Gold Solution 8 Gramm / Liter
PRODUCT PRESENTATION - GOLD ELECTRTOLYT 999 FINE GOLD - 23,8 CARAT  WITH 8 GRAMS OF GOLD PER LITER   Do-it-yourself gold plating has never been so easy. Our gold electrolyte from Betzmann Galvanik may be purchased by anyone. Whether it is for use in highly professional laboratories, industry, luxury companies, to the use in the hobby, main or secondary trade, companies, schools, universities, TH , IHK or other authorities. With this extremely fast and very hard depositing gold electrolyte from Betzmann Galvanik, you can usually coat the following metals directly: Stainless steel of all kinds, surgical steel, copper, silver, brass, nickel, iron, steel,   The pink color of the electrolyte is the hardness additive cobalt. This gives the otherwise much too soft gold an abrasion resistant surface. This is not toxic in the admixed composition.  The gold electrolyte from Betzmann Galvanik is anti-allergenic, was extracted from crisis- and conflict-free gold and is food-safe.  Our Betzmann Galvanik Gold Electrolyte has a very fast deposition and further achieves a very hard gold layer. It has a very good covering effect and is therefore one of the best products on the market worldwide. A special preservative causes a very long shelf life of at least 2 years and prevents sedimentation, as it occurs with many other gold electrolytes. The gold electrolyte from Betzmann Galvanik is used worldwide, e.g. for the gold plating of boat parts made of brass that are exposed to salt water, medical technology, measurement technology, for optical gold plating, for technical gold plating, gold plating of drive shafts, musical instruments and their parts, both inside and outside, body jewelry, intimate protection, dental jewelry, dental technology, drills of all kinds, shisa, e-cigarettes so-called. Vaporizers, vehicle parts, engine parts, motorcycle parts, airplane interiors, exhaust systems and manifolds, as gold is very heat resistant, sporting goods, diving equipment, keys and pendants, jewelry, chains and rings of all kinds, piston rods, pipes, table feet, bathroom fixtures and many more. Partial coatings are possible by masking and masking surrounding areas. To avoid material loss when coating sloping surfaces, we recommend our thickener/gel former. With this you can thicken all electrolytes also chrome remover, cleaner etc..   Also you can use with this gold mostly in the ratio 1:10 our mixer products like rose gold, white gold and green gold! Optimal results are achieved with the platinum electrode 6mm - 10cm length or the flat platinum electrode, because platinum electrodes can build up very thick layers far over 10 microns and more. Graphite electrodes can also be used.  Gold content: 8 grams per liter    The procedure for gilding: Recommended to first polish the surface to a shine - the nicer the surface, the nicer the shine will be Thorough degreasing with the electrocleaner Activate the surface with the activator Gilding with platinum electrode starting around 5 volts     Voltage Range 3.0 – 8 volts Temperature 14 – 25 °C Gold Concentration 8 g/l Electrode Platinum or Carbon (see notes) Gold content in plate 99.9% (balance carbon) Plating Rate at (3.5 volts, Platinum electrode) Approx. 0.7 micron per minute (spot) Hardness 220 – 230 Hv Density of deposit 19.0 g/cm3 Stress Medium stress Special storage requirements Away from sunlight Shelf life 1 – 2 years     Signalword: Warning H-phrases:H332 Harmful by inhalation.H312 Harmful in contact with skin.H302 Harmful if swallowed.EUH032 Contact with acids liberates very toxic gas.P phrases:P280 Wear protective gloves/protective clothing/eye protection/face protection.P301 IF INSPECTED:P310 Immediately call a POISON CENTER/doctor.

Content: 0.05 Liter (€1,213.80* / 1 Liter)

From €60.69*