Nickelstripper

€25.00*

Content: 0.25 Liter (€100.00* / 1 Liter)
(€21.01 ohne MwSt.)

Available, delivery time: 1-2 days

ml
Product number: SW10014
PDF offer
Create PDF offer for this product Tip: Add multiple products to the cart and create the offer there. Logged in users get an individualized offer.
Product information "Nickelstripper"

Nickel stripper strips nickel plating from steel, copper, brass and silver easily and delivers the following pluses;

  • Ready-to-use solution: no need for mixing
  • Low hazzard
  • Stripping rates of up to 50 microns per hour at 62 °C
  • High capacity (1 litre can strip 40 grams of nickel)
  • Low odour: minimum ventilation needed
  • Supplied as a one-component, ready-to-use solution
  • Non-electrolytic stripper: no need for a separate rectifier
  • Long bath life
  • Can be shipped worldwide

Operating Conditions

Temperature Range 50 -65 °C (see notes)
Tank Glass (see notes below), steel or polypropylene
Agitation Mechanical (stirrer). Never use air agitation
Stripping rate See notes below
Stripping capacity Can strip up to 40 grams of nickel per litre
Special storage requirements None
Shelf life 1 – 2 years
Health and Safety classification Irritant
Special considerations None
Transport (UN number) None: Not classified as dangerous for transport

 

Notes:

  • Tanks should be made of stainless steel, polypropylene or glass. If using glass,
    return the solution (cooled) to the container after use.
  • Heating should be provided by a Teflon-coated stirring bar (if stripping in a beaker).
  • For larger installations, stainless steel or titanium-sheaved heaters should be used.
  • Stripping rates can be almost doubled by using light mechanical agitation:
  • Stripping rate at 50°C = 10  microns per hour (no agitation)
  • Stripping rate at 50°C = 17  microns per hour (with agitation)
  • Stripping rate at 62°C = 50 microns per hour (with agitation)
  • Black smut remaining can be removed by ultrasonic cleaning or scouring with pad.

 

madeingermany-betzmann

 

Nickelentferner 


GHS07

GHS07 - Signal word: Caution

 

H-phrases:

H317: May cause an allergic skin reaction.

P-phrases:

P102: Keep out of the reach of children.

P260: Do not breathe aerosol.

P280: Wear protective gloves / eye protection.

P302 + P352: IF ON SKIN: Wash with plenty of water.

P501: Dispose of contents/container to hazardous waste.

0 of 0 reviews

Leave a review!

Share your experiences with other customers.


Similar Items

Chrome Stripper
Chrome remover - Chrome stripper from Betzmann Galvanik :   Our chrome remover effortlessly removes any layer of chrome, regardless of its thickness, and also cleans the surface. Please note: The chrome remover only works with alternating polarity. Handle minus and crocodile clip PLUS. The chrome dissolves yellow and therefore also serves as a test to determine whether the material is actually chrome-plated. The chrome remover does not attack paints and varnishes.   You can remove any chrome quickly and safely with our chrome remover. But what is chrome removal for? It's simple: chrome-plated components are usually coated with an oxide layer and therefore cannot be electroplated.  therefore cannot be electroplated. During dechroming, the chrome layer is removed and the layer underneath is available for electroplating.  available for electroplating. For example, after dechroming, you can coat previously chrome-plated rims or car parts or  all chrome-plated parts yourself. The gloss of the surface is not affected.    You can use the Betzmann electroplating dechromer to Dechrome lettering Dechroming fittings Dechroming rims Dechroming exhaust pipes General chrome removal from chrome-plated components The use of our chrome remover applies to immersion electroplating and pin electroplating / manual electroplating.    Connect the object from which you want to remove the chrome to the positive pole (red) of the power supply unit using a clamp.  Then connect the pin to the negative pole (black). Set a voltage of 6 volts or more and use the pad to pick up the chrome remover.  pick up the chrome remover. Then touch the workpiece with the pad and slowly move the pen around on the chrome surface.  The chrome will turn yellowish.   You can find more detailed instructions on how to carry out the procedure and safety instructions for dechroming in our instructions for use for this product   (see links and downloads).   Operating Parameters   For Brush Stripping   For Tank Stripping Plating Factor –   0.01 – 0.04 A/cm2 Voltage 4 – 6 volts   4 – 6 volts Temperature Room   Room Agitation –   Optional (stirrer) Work piece polarity Positive   Positive Electrode/Anode Carbon (preferred), stainless steel or platinum   Stainless Mesh Electrode (recommended)or Mesh Electrode Processing time 2 microns per minute at 5 volts   1 micron per minute a 5 volts Shelf Life (bottled) Over 5 years   Over 5 years     Labeling according to EC Regulation No. 1272/2008          Signal word: Caution - Corrosive   Precautionary statements: P101 If medical advice is needed, have product container or label at hand.  P102 Keep out of the reach of children.  P260 Do not breathe dust/fume/gas/mist/vapor/spray. P264 Wash hands thoroughly after handling.  P272 Do not wear contaminated work clothing outside the workplace.  P280Wear protective gloves/protective clothing/eye protection/face protection.  P301+P330+P331 IF SWALLOWED: Rinse mouth. DO NOT induce vomiting.  P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Wash skin with water/shower.  P321 Specific treatment (see instructions on this label).  P333+P313 If skin irritation or rash occurs: Get medical advice/attention.  P321 Special treatment (see instructions on this label).  P333+P313 If skin irritation or rash occurs: Get medical advice/attention.  P352 Wash with plenty of soap and water.  P363 Wash contaminated clothing before reuse. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P310 Immediately call a POISON CENTER or doctor.  P321 Specific treatment (see instructions on this label).  P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if possible. Continue rinsing.  P310 Immediately call a POISON CENTER or doctor. P405 Keep locked up  

Content: 0.25 Liter (€38.00* / 1 Liter)

€9.50*
Chromplating - Chrome solution
Chrome electrolyte - chrome plating with Betzmann Galvanik   Chrome plating by yourself with high-quality chrome electrolyte from Betzmann Galvanik  A layer of chromium protects a wide variety of components from oxidation and corrosion. In addition, the workpiece is given a visually appealing appearance. Our electrolyte is based on chrome(III). While chromium(VI) was originally used in the industrial process, chromium(III) electrolytes are increasingly being used because they have a significantly lower impact on man and nature. This electrolyte contains all our know-how - we were able to make it significantly brighter and more efficient. Current densities up to 20A/dm² can be achieved. Usually chrome is deposited in the layer system copper - nickel - chrome. The intermediate layer of nickel provides additional protection against corrosion, as chrome layers show microcracks. T   Of course, the chrome electrolyte is suitable for all processes such as bath electroplating and pen plating (or pad plating). When chromium plating, always wear the necessary protective equipment such as safety goggles, gloves and protective clothing and only work in a well-ventilated room.   Parameters (these may vary, please test): Bath electroplating: 1.5-6V (approx. 3V recommended at 10cm distance) pin plating: 3-7V (approx. 4-5V recommended) Current density: 4-24A/dm² (up to 50A/dm² with bath movement) Working temperature 20-50°C (25°C recommended) deposition rate: 0.06µm/min at 10A/dm²   The most important advantages at a glance:  is equally suitable for bath electroplating and pen plating / pad plating high adhesive strength and abrasion resistance high hardness up to 1200 HV extremely large current density range appealing optics Color of the chrome layer is very similar to the result of hexavalent chrome baths heating of the electrolyte is not necessary (temperature range 15-50°C, preferably 15-30°C) high reflection and beautiful gloss higher permissible metal impurities than with other processes, thus easier to use    To achieve a perfect result with the chrome electrolyte, the appropriate anodes are required for the galvanic process used. Anodes made of aluminum, platinized titanium, platinum or iridium are recommended. For pen plating, graphite, nickel or stainless steel anodes can be used if necessary. With nickel or stainless steel anodes, however, it is important to ensure that the pad is washed out well in between so that the metal contamination that arises does not contaminate the electrolyte and the chromium layer.   Aluminium anodes have proven to be particularly advantageous, they are particularly cost-effective and the electrolyte retains its excellent color. If you do not have any, we recommend that you order them directly from us.   Identification of the mixture: Chrome Electrolyte (contains chromium hydroxide sulfate, boric acid, ammonium chloride, ammonium formate) Signal word: Caution H-phrases: H317: May cause an allergic skin reaction. P phrases: P261: Avoid inhalation of aerosol. P280: Wear protective gloves / eye protection. P302 + P352: IF ON SKIN: Wash with plenty of water. P333 + P313: If skin irritation or rash occurs: Get medical advice/attention. P101: If medical advice is needed, have container or label at hand. P102: Keep out of the reach of children.             

Content: 0.1 Liter (€116.60* / 1 Liter)

€11.66*
Chrome Plating Kit
BMG-25A - Electroplating line - complete basic equipment with electrolyte set for chrome       With this complete set you achieve absolutely perfect results!   No matter what size, whether 10 meters of railing or a 28 inch rim, this machine can coat any surface.   With 100 ml electrolyte you usually manage 1m2, so it is quite productive!   With this electroplating unit you can easily coat all metallic surfaces and objects made of e.g. tin, zinc, brass, copper, nickel, silver and stainless steel and chromed surfaces or chromed plastic (conductive layer) with all metals available on the market. e.g. real gold (999 fine gold) - rose gold, white gold, antique gold - silver - nickel - alkaline or acid copper - chrome - black chrome - rhodium - black rhodium - palladium - platinum - zinc, tin - bronze - in other words everything we have on stock according to our price list.     Scope of delivery: 1x Power Rectifier, galvanic unit depending on availability with 25 A digital or analog, adjustable 2.5 to 15 Volt, power cord,            1x cable PLUS  1x cable MINUS with clamp 1x handle 3x stainless steel electrodes thick 6mm 1x Aluminium Electrode for Chromplating 6mm  6x sleeves   6x cups with lid, scaled   250 ml chrome  250 ml Nikel   250 ml Copper alkali   250 ml chrome remover for dechroming  250 ml Electrocleaner for degreasing  250 ml activator     Manual in German or English, training films, guides via PDF / E-MAIL  Free personal technical support, 12 months warranty, free personal training and support, unlimited and free advice from our team   Immediately ready for gilding! Can be supplemented with chrome - black rhodium - silver and much more.    High Power 25 or 40 Amp switch mode power supply with two analog measuring instruments for output voltage and output current -    Technical data    Operating voltage 230 Volt-AC/ 50Hz Output voltage 3-15 Volt DC adjustable or 13,8 Volt DC fixed voltage by fixed voltage switch on the bottom side Output current 25 amps constant 25 amperes short-term Ripple & Noise <50mV load regulation <200mV line regulation <50mV Displays & movements Analogue meter for voltage and current, status Bi-colour LED red ( fault ) and green DC connection sockets screwable pole terminals Cooling Fan Security Protection against overload, overheating, short-circuit and reverse polarity protection, output voltage protection from 16.5 volts Extras dark grey metal housing with rubber feet, high efficiency > 78% by PFC (Dynamic Power Factor Correction) >0.95 maximizes the required current, high RFI stability Dimensions(WxHxD) 220x110x300 mm Weight 3.5 Kg.    

From €279.65*
Rust Remover
Rust Remover from Betzmann Galvanik! RUST REMOVER: Combined chemical agents and selected polishing clays result in a unique formulation for reviving heavily corroded metal objects. After removal, the natural protection of the metal is restored, corrosion inhibitors prevent attack on uncorroded parts.   Ingredients: AQUA, ALUMINA, HYDROCHLORIC ACID, fatty alcohol polyglycol ether, fatty acids, 2-propyn-1-ol, compound with methyloxirane, XANTHAN GUM, COCAMIDOPROPYL BETAINE , prop-2-in-1-ol. Information on ingredients according to the Detergents Directive - Annex VII D, EC -648/2004 is available on the EU portal "European List of Cosmetic Ingredients".        GHS05 GHS07  Danger. Causes severe skin burns and eye damage. May cause respiratory irritation. If medical advice is needed, have packaging or label at hand. Keep out of the reach of children. Wear protective gloves / protective clothing / eye protection / face protection. Do not breathe vapor. IF ON SKIN (or hair): Remove all contaminated, soaked clothing immediately. Wash skin with water/shower. IF IN EYES: Rinse cautiously with water for several minutes. Remove existing contact lenses if possible. Continue to rinse. Contains: Fatty alcohol polyglycol ether, hydrochloric acid.  

Content: 0.1 Liter (€131.00* / 1 Liter)

€13.10*
Aluminum Activator
Aluminum Pretreatment - Aluminum Activator  A metallically pure surface is essential for successful electroplating.  Aluminum (Al) is a base metal (with a normal potential of -1.6 V) and forms a dense oxide layer within a short time.  a dense oxide layer within a short time. Reliable plating is impossible on an oxide layer.  In order to coat aluminum nevertheless, an intermediate layer, a so-called "zincate layer" is usually is applied. The material can then be gold-plated, copper-plated or otherwise electroplated.  The aluminum activator works perfectly with pure aluminum, and with many Al alloys as well.  should be tested in advance.     Especially aluminum-silicon alloys do not work at all. Please coat only with alkaline copper! This product contains acid. However, you will receive a detailed guide so that you can work safely. We offer here a solution with reduced viscosity, because this has many advantages.   The advantages are: - the lower viscosity reduces the entrapment of the solution in porous casting molds (blistering of the subsequent coating) - lower loss of chemicals (especially in unfavorable molds) - faster deposition - higher safety of deposition on aluminum alloys containing magnesium and silicon.   Aluminiumpreparer: Now you can plate It! Operating Conditions and Deposit Data Temperature 18 – 25 °C Immersion time 30 seconds to 2 minutes (see notes) Thickness of zinc film 0.1 – 0.2 microns Agitation Occasional work movement. Appearance of deposit Grey continuous layer Special storage requirements Away from strong acids Shelf life 1 – 2 years Health and Safety classification Irritant Special considerations None Transport (UN number) 1824 Notes: The aluminium article should be dipped until a contiuous grey film appears. If left in the solution too long, the adhesion of the zinc film is reduced, leading toblistering and in extreme cases, lifting of the plating. To strip the zincated layer, dip in Cleaner  for 10 minutes. Please note that oncethe Cleaner has been used for stripping, it cannot be used for any other process.     Marking of the mixture: Aluminum activator (contains sodium hydroxide)     Signal word: Danger H-phrases: H290: May be corrosive to metals. H314: Causes severe skin burns and eye damage. H412: Harmful to aquatic life with long lasting effects. P phrases: P102: Keep out of the reach of children. P234: Keep only in original container. P260: Do not breathe aerosol. P280: Wear protective gloves / eye protection. P301 + P330 + P331: IF INTOXICATED: Rinse out mouth. Do NOT induce vomiting. P303 + P361 + P353: IF IN CONTACT WITH SKIN (or hair): Remove all contaminated clothing immediately. Wash skin with water/shower. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove existing contact lenses if possible. Continue to rinse. P501: Dispose of contents/container to hazardous waste.  

Content: 0.1 Liter (€83.30* / 1 Liter)

€8.33*
Nickel Free
Galvanic Nickel Electrolyte from Betzmann Galvanik for self-nickel plating Nickel Plating Solution   Our absolutely high-quality galvanic nickel electrolyte has been specially developed for self-nickel plating and may be sold to private individuals without an end-use declaration.   Depending on the material of the workpiece as well as the detailed procedure of nickel plating you will achieve the following results: reliable corrosion protection by a layer combination such as copper-nickel chemically resistant protective layer against diluted acids, alkalis as well as air and water diffusion protection for subsequent electroplating (e.g. diffusion from a base copper layer into the covering gold layer) decorative protective coating with a high-gloss surface, which also serves as wear protection. As an electroplating nickel electrolyte, our product is suitable for bath electroplating as well as for pin electroplating and pad electroplating. During nickel plating, the magnetic properties of the workpiece are retained and it exhibits a high-gloss silver-like color with a subtle yellow tint. Just as convincing as the final result is the high deposition rate exhibited by the nickel electrolyte. Electroplated nickel - decorative or protective coating   If a simply formed workpiece or component is to be provided with a protective layer, we recommend the combination of copper and nickel. In this way, you immediately achieve reliable corrosion protection, which you would otherwise only achieve with pure nickel plating with a layer thickness of 25 to 50 µm. Only at these thicknesses does the coating have the required freedom from pores, since nickel electrolytes always deposit with fine pores. However, electroplated nickel not only protects against corrosion. The coating, which is uncomplicated to apply, is highly resistant to dilute acids and alkalis and serves as wear protection. If several electroplating steps with layers of different metals are planned, an electroplated nickel electrolyte can be used as a barrier layer. In this way, you prevent diffusion or color mixing of different layers. In all processes, it is irrelevant whether you use our nickel electrolyte for bath electroplating or for pin electroplating and pad electroplating. For decorative plating, the combination of bright nickel and chrome is ideal for reliably achieving flat surfaces, although pure bright nickel plating may be sufficient depending on the application.   Application instructions for Betzmann Galvanik's Free Nickel Nickel Electrolyte (bright nickel) Our high-performance Free Nickel Nickel Electrolyte is preferably processed at room temperature (range from 15 to 60 °C). It is suitable for all common metals, semi-precious and precious metals with the exception of aluminum, chrome (dechrome beforehand) and titanium.   If you plan to nickel plate stainless steel yourself, please be sure to use a nickel strike for pretreatment or gold plate in advance with Goldflash. to increase adhesion.   Before galvanic nickel plating, clean the workpiece particularly thoroughly. Remove rust completely and degrease the component, e.g. with isopropanol. Be sure to work with clean disposable gloves to avoid transferring skin grease to the workpiece.   The nickel electrode from Betzmann Galvanik is particularly recommended - this results in a very high range, as the nickel is permanently enriched.   Please pay attention to the following recommendations, depending on the electroplating method used. Parameters: Bath electroplating: 2-5V (approx. 3V recommended at 10cm distance) Pin electroplating: 6-12V (approx. 8-9V recommended) Current density: 0.3-1.2A/dm² (up to 3A/dm² with bath movement) Working temperature: 15-60°C pH value: approx. 4 (can be corrected e.g. with 10% sulphuric acid) Deposition speed: approx. 0.3µm/min at 1A/dm² and 20°C   Identification of the mixture: Signal word: Caution Free nickel (contains nickel sulfate, nickel dichloride, nickel bis(sulfamidate), nickel di(acetate), diammonium nickel bis(sulfate)) GHS07 H317 May cause an allergic skin reaction. H412 Harmful to aquatic life with long lasting effects. P102 Keep out of the reach of children. P103 Read all instructions carefully and follow them. P261 Avoid breathing dust/vapor/aerosol. P280 Wear protective gloves and eye/face protection. P302+P352 IF ON SKIN: Wash with plenty of water. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P501 Do not dispose of contents/container with household waste and dispose of in accordance with regional/national regulations.        

Content: 0.1 Liter (€91.60* / 1 Liter)

€9.16*